Long-term and successful cooperation with HAUBER-Elektronik GmbH has resulted in an exclusive representation for the Czech and Slovak Republic.
We use Hauber sensors both in the equipment we manufacture and supply (centrifuges, cooling towers) and as the exclusive representative of HAUBER-Elektronik GmbH we offer them as separate components. Technical support provided by our company is a matter of course.
Hauber sensors are compact but very powerful vibration sensors.
Type HE 200 / HE 205, also in the version ,, Ex,, SIL 2/PL d , is certified for most continents of the world. The indisputable advantage is that the sensor does not need an additional evaluation unit, on the contrary everything is compactly contained in one all stainless steel sensor body.
Basic characteristics Hauber HE 200 / HE 205:
- output loop 4 -20 mA
- setting values directly on the LM1/LM2 sensor
- digital output PNP or NPN
- own internal diagnostics
- vibration speed sensing [mm/s, rms]
- vibration acceleration sensing [g, rms]
- measuring range by device
Type HE100 | HE101 | HE102 | HE103 with analogue output in all stainless steel design and suitable also for hazardous areas „Ex approvals in Ex ib or Ex tb zone 1/21: Zone 2/22:- cULus Haz. Loc DIV2“ provides complete monitoring of rotating machines including evaluation of their condition
Basic characteristics Hauber HE100 | HE101 | HE102 | HE103:
- vibration speed sensing [mm/s, rms]
- vibration acceleration sensing [g, rms]
- temperature sensing [°C]
- measuring range by device


- Vibration speed (mm/s, rms)
- Vibration acceleration (g, rms)
- Vibration acceleration (g, peak)
- Temperature (°C)
- Output 1: IO-Link or
Digital switching output
- Output 2: Analog electrical output 4-20 mA or
Digital switching output
- Frequency bands configurable: 10-1000 Hz


- Vibration speed (mm/s, rms)
- Vibration acceleration (g, rms)
- Vibration acceleration (g, peak)
- Temperature (°C)
- Output 1: IO-Link or
Digital switching output
- Output 2: Analog electrical output 4-20 mA or
Digital switching output
- Frequency bands configurable: 10-1000 Hz


- Vibration speeds (mm/s, rms)
- ATEX / IECEx / UKEx / EACEx, Zone 1 / 2 / 21 / 22
- Analog electrical output: 4...20 mA
- Frequency bands: 10 Hz ... 1000 Hz
1 Hz ... 1 000 Hz


- Vibration speeds (mm/s, rms)
- ATEX / IECEx / UKEx / EACEx, Zone 1 / 2 / 21 / 22
- Temperature (°C)
- Analog electrical output: 4...20 mA
- Frequency bands: 10 Hz ... 1000 Hz
1 Hz ... 1 000 Hz


- Vibration acceleration (g, rms)
- ATEX / IECEx / UKEx / EACEx, Zone 1 / 2 / 21 / 22
- Analog electrical output: 4...20 mA
- Frequency bands: 10 Hz ... 1000 Hz
1 Hz ... 1 000 Hz


Vibration speeds (mm/s, rms)
- ATEX / IECEx / UKEx / EACEx, Zone 1 / 2 / 21 / 22
- Analog electrical output: 4...20 mA
- Frequency bands: 10 Hz ... 1000 Hz
1 Hz ... 1 000 Hz
- Extended averaging time RMS T = 60 s


- Vibration speed (mm/s, rms)
- Vibration acceleration (g, rms)
- ATEX / IECEx / UKEx, zone 2/22 and 1/21
- cULus OrdLoc / HazLoc Div 2
- 2 voltage-free switching contacts
- Analog electrical output: 4...20 mA
- Frequency bands: 10 Hz ... 1000 Hz
1 Hz ... 1 000 Hz


- Vibration acceleration (g rms)
- ATEX / IECEx / UKEx, zone 2/22 and 1/21
- cULus OrdLoc / HazLoc Div 2
- 2 voltage-free switching contacts (Window function)
- Analog electrical output: 4...20 mA
- Frequency bands: 10 Hz ... 1000 Hz
1 Hz ... 1 000 Hz
They ensure safe shutdown of machinery in the event of exceeding or exceeding defined vibration limits.

- Evaluation: type 648 or HE101
- Display: vibration rate („vibration“)
in mm/s rms, temperature in °C
- Relay: - Preliminary alarm (limit 1),
- Main alarm (Limit 2),
- OK

- Evaluation: 2x Type 640, 664 or HE100
- Display: vibration rate („vibration“)
in mm/s rms, temperature in °C
- Relay: - Preliminary alarm (limit 1),
- Main alarm (Limit 2),
- OK

- Evaluation: type 640, 664 or HE100
- Relay: - Main alarm (Limit 2),
- OK

Measurement of the vibration rate in accordance with
DIN ISO 10816